HomeProductsSerial Device ServersIOT9031A

IOT9031A

Three-in-One Serial Device Server

Connect RS232, RS485 and RS422 equipment to Ethernet with transparent data transfer and Modbus RTU/TCP pass-through.

Bridge three common industrial serial interfaces to 10/100M Ethernet through configurable TCP and UDP server or client modes.

RS232 / RS485 / RS42210/100M EthernetTCP / UDPModbus RTU/TCP
Serial InterfacesRS232 / RS485 / RS422Three-in-one connectivity
Ethernet10/100M RJ45Full / half duplex adaptive
Network ModesTCP / UDPServer and client
Protocol GatewayModbus RTU/TCPBidirectional pass-through
Power InputDC 5VIOT9031A(5V) hardware

Product Overview

A practical path for bringing installed serial equipment into modern industrial data networks.

The IOT9031A integrates a TCP/IP protocol stack to exchange data transparently between Ethernet networks and RS232, RS485 or RS422 serial equipment.

TCP Server, TCP Client, UDP Server and UDP Client modes support different network architectures. The legacy source also documents Modbus RTU/TCP bidirectional pass-through and combined use of RS232 with either RS485 or RS422.

3serial standards

RS232, half-duplex RS485 and full-duplex RS422 support.

10/100Madaptive Ethernet

RJ45 network connection compatible with IEEE 802.3.

>1200msource-stated reach

Long-distance serial communication for distributed field equipment.

4network modes

TCP and UDP server or client operation.

Key Features

Core capabilities selected for reliable integration, flexible deployment and efficient maintenance.

Three Serial Interfaces

Connect RS232, RS485 or RS422 equipment through one serial-to-Ethernet platform.

Transparent Bidirectional Transfer

Transfers serial data and Ethernet packets in both directions without changing the application payload.

Modbus RTU/TCP Pass-Through

Supports bidirectional Modbus RTU/TCP communication for industrial monitoring and control systems.

Flexible TCP and UDP Modes

Configure TCP Server, TCP Client, UDP Server or UDP Client operation for the target network.

Adaptive Ethernet

The RJ45 port supports 10/100M Ethernet with full- or half-duplex adaptation.

Wall-Mount Metal Enclosure

A compact metal housing with mounting flanges and RXD, TXD and power indicators supports fixed installations.

Industrial Applications

Explore practical deployment scenarios for this DTECH industrial connectivity product.

Industrial Automation application for IOT9031A

Industrial Automation

Connect PLCs, controllers and serial instruments to plant Ethernet networks.

Smart Transportation application for IOT9031A

Smart Transportation

Network signal controllers and roadside serial equipment for centralized monitoring.

Access Control application for IOT9031A

Access Control

Integrate serial access controllers and attendance equipment with IP-based management systems.

Energy and Data Acquisition application for IOT9031A

Energy and Data Acquisition

Collect data from meters and Modbus RTU field devices through Ethernet.

System / Network Architecture

See how this product fits into an industrial serial communication network.

RS232 / RS485 / RS422 DevicesController, meter, sensor or serial instrument
Serial data
IOT9031A in system architecture
IOT9031ATransparent serial-to-Ethernet and Modbus RTU/TCP gateway
Protected branches
Ethernet Monitoring SystemSCADA, server, PC or centralized control platform

Technical Specifications

Verified configuration details for engineering review and product selection.

Hardware and Interfaces
Model
IOT9031A (5V version)
Serial interfaces
RS232, RS485 and RS422
RS485 mode
Half duplex
RS422 mode
Full duplex
Ethernet port
1 × RJ45, 10/100M adaptive
Ethernet compatibility
IEEE 802.3; full / half duplex adaptive
Power input
DC 5V
Controls and indicators
Reset switch; RXD, TXD and PWR indicators
Mounting
Wall-mount flanges
Communication and Network
Network operating modes
TCP Server, TCP Client, UDP Server and UDP Client
Data transmission
Bidirectional transparent transfer between serial and Ethernet data
IP configuration
DHCP supported
Domain access
DNS supported
Industrial protocol
Modbus RTU/TCP bidirectional pass-through
Serial transmission distance
More than 1200 m as stated by the legacy product source
Dual-interface operation
RS232 with RS485, or RS232 with RS422; RS485 and RS422 are not used together
Documented Factory Defaults
Operating mode
TCP Server
Device IP
192.168.1.200
Subnet mask
255.255.255.0
Default gateway
192.168.1.1
Module port
2000
Serial framing
9600 bps, 8 data bits, 1 stop bit, no parity
Package Contents
Included
1 × serial server; 1 × power adapter; 1 × product instruction card
Terminal accessory
1 × 3.81 mm 6-pin terminal block for applicable serial connections

Downloads

Access product documentation for setup, integration and technical review.

IOT9031 Series English User Manual

English instructions covering IOT9031, IOT9031A and IOT9031B interfaces, defaults, network modes and accessories.

PDF0.8 MBEnglish

Frequently Asked Questions

Verified answers for product selection and project planning.

Which serial interfaces does the IOT9031A support?

The IOT9031A supports RS232, half-duplex RS485 and full-duplex RS422 serial communication.

Which TCP and UDP modes are available?

It supports TCP Server, TCP Client, UDP Server and UDP Client operation.

Can RS232 and RS485 be used together?

Yes. The legacy source states that RS232 can be used with RS485, or RS232 can be used with RS422. RS485 and RS422 are not used together.

Does the IOT9031A support Modbus?

Yes. The official product information and manual document Modbus RTU/TCP bidirectional pass-through.

What power input does this hardware version require?

The supplied IOT9031A(5V) hardware image and its product label specify DC 5V input.

Need Help Selecting the Right Product?

Share your device interfaces, network environment and project requirements with the DTECH industrial communication team.

Contact Sales
Download PDF